The tensile strength of steel fiber reinforced concrete can be determined by multiplying the split tensile strength obtained by the test by the strength reduction factor of 0.80. The split tensile strength test method is carried out according to the provisions of GB J81.
Standard value of tensile strength of steel fiber reinforced concrete fftk=ftk(1+αt·ρf·lf/df)
fftk, ftk——Standard value of tensile strength of steel fiber reinforced concrete, design value;
αt——Influence coefficient of steel fiber on tensile strength of steel fiber reinforced concrete, which should be determined by experiment;
ρf——Steel fiber volume ratio (that is, the volume ratio of steel fiber content)
lf - steel fiber length
df - steel fiber diameter or equivalent diameter
lf/df——steel fiber aspect ratio

Flexural tensile strength (flexural strength) of steel fiber reinforced concrete
When steel fiber reinforced concrete is used for highway pavement, airport pavement, or other structures with flexural tensile strength as the design index, the classification and use range of the design value of flexural tensile strength of collective concrete corresponding to steel fiber reinforced concrete may be determined according to the current national regulations. Cement concrete pavement, airport pavement and other industry design specifications shall be adopted.
Design value of flexural and tensile strength of steel fiber reinforced concrete fftm=ftm(1+αtm·ρf·lf/df)
fftm, ftm——Standard value of tensile strength of steel fiber reinforced concrete, design value;
αtm——Influence coefficient of steel fiber on tensile strength of steel fiber reinforced concrete, which should be determined by experiment;
ρf——Steel fiber volume ratio (that is, the volume ratio of steel fiber content)
lf - steel fiber length
df - steel fiber diameter or equivalent diameter
lf/df——steel fiber aspect ratio